Method¶
The brightness measurement method used by the automatic brightness control.
By default, the automatic brightness control analyzes the histogram of the captured image and steers the gray values at the configured quantiles towards their target values, see Target/Shadow/Quantile and Target/Highlight/Quantile.
Setting this node to Mean switches to the legacy mean-based brightness control, which steers the average image brightness towards Target/Mean instead. Switching to Mean sets Target/Mean to a default of 80 if it was disabled, and switching back to Quantiles sets Target/Mean back to -1.
Note
When Mean is selected, Hdr/Automatic is ignored and the HDR state remains what it was before switching to Mean.
JSON Format¶
- Type
String- Default Value
"Quantiles"
Values¶
Value |
Description |
|---|---|
|
Steer the gray values at the configured histogram quantiles towards their target values. |
|
Steer the mean gray value of the image towards Target/Mean. |